Correlation between the Closest Pin Distance of the Fracture line to the Stability of the External Fixation: A Biomechanical Study on Bovine Tibia

Donny Artya Kesuma *

Department of General Surgery, Faculty of Medical, dr. Moewardi Hospital, Universitas Sebelas Maret, Surakarta, 57126, Indonesia.

Udi Heru Nefihancoro

Department of Orthopaedic and Traumatology, Medical of Faculty, dr. Moewardi Hospital, Universitas Sebelas Maret, Surakarta, 57126, Indonesia.

Hari Wujoso

Department of Forensic and Medicolegal, Medical of Faculty, dr. Moewardi Hospital, Universitas Sebelas Maret, Surakarta, 57126, Indonesia.

*Author to whom correspondence should be addressed.


Abstract

Aims: To determine the effect of the closest pin distance from the fracture line on the stability of the external fixation which is applied axial compression force.

Study Design:  This study was an experimental study with a post-test only controlled group design, using bovine tibia.

Place and Duration of Study: This research was conducted in the Orthopedic and Traumatology Department of Dr. Moewardi Hospital and Engineering Laboratory of Sebelas Maret University from June to September 2020.

Methodology: External fixation stability measured using a Universal Testing Machine. There were three treatment groups with different closest pin spacing (2 cm, 3 cm, 4 cm).

Results: This study used 30 bovine tibial bones (10 bones for each treatment group). The closest 2 cm pin distance group has the largest mean value of compressive strength 7036.56 ± 453.37 Newton. Linear regression analysis shows the value of p = 0.000 with a regression coefficient of -912.55. The significant relationship proves the near-far law theory, where the pins are placed as close as possible from the fracture line could give the greater amount of external fixation stability.

Conclusion: Shorter pin distances from the fracture line were associated with increased compressive strength.

Keywords: Axial compression, closest pin distance, bovine tibia, external fixation stability


How to Cite

Kesuma, Donny Artya, Udi Heru Nefihancoro, and Hari Wujoso. 2021. “Correlation Between the Closest Pin Distance of the Fracture Line to the Stability of the External Fixation: A Biomechanical Study on Bovine Tibia”. Asian Journal of Research in Surgery 4 (1):118-23. https://journalajrs.com/index.php/AJRS/article/view/74.

Downloads

Download data is not yet available.